«Spetszhelezobeton» JSC


Non pressure pipes

 

Non pressure pipes

Length 5m

STB 1163-99, working drawings, series ÁÇ.008.1-1, release 5.

Diameter, mm

600

1000

1200

1400

1600

Pipe mark

ÒÁ 60.50-3

ÒÁ 100.50-3

ÒÁ 120.50-3

ÒÁ 140.50-3

ÒÁ 160.50-3

Volume, m³

0,76

1,42

1,98

2,66

3,28

Weight, t

1,9

3,6

5,0

6,7

8,2

Thickness of the wall of a pipe, mm

65

75

85

95

105

Useful length, mm

5000

5000

5000

5000

5000

Norm of loading in the semicar, items

22/16

10/6

6/4

2

2

· Are made of heavy concrete of a class Ñ25/30 (Â30) – for the pipes of the 3rd group on bearing ability with 6 meter depth of plunging to pipe top, and Ñ32/40 (Â40) – for the pipes of the 3rd -y group on bearing ability with 10 meter depth of plunging to pipe top.

· Mark of concrete on water resistance is not bellow than W 6.

· Mark of concrete on frost resistance – F 200.

· Mark of concrete on water absorption – not more than 6 %.

Sealing elements from rubber are used for weatherproofing of butt connection of pipes.

 

 

 

Length 2.5m

(applied methods: radial pressing and vibration pressing) STB 1163-99, working drawings, series ÁÇ.0081-1, release 7, 8, 9; working drawings " Reinforced concrete non pressure vibration pressed pipes in diameter 1600 mm, 2000, 2400 mm of deep plunging".

Diameter, mm

300

400

500

600

800

Pipe mark

ÒÁ 30.25-2

ÒÁ 30.25-3

ÒÁ 40.25-2

ÒÁ 40.25-3

ÒÁ 50.25-2

 ÒÁ 50.25-3

ÒÁ 60.25-2

 ÒÁ 60.25-3

ÒÁ 80.25-2

 ÒÁ 80.25-3

Volume, m³

0,19

0,26

0,37

0,47

0,67

Weight, t

0,425

0,60

0,9

1,125

1,64

Thickness of the wall of a pipe, mm

55

55

70

75

80

Useful length, mm

2500

2500

2500

2500

2500

Norm of loading in the rail car, items

96

60

44

44

20

 

 

Table continuation

Diameter, mm

1000

1600

2000

2000

with a sole

Pipe mark

ÒÁ 100.25-2ó[1]

ÒÁ 100.25-3ó

ÒÁ 100.25-2

ÒÁ 100.25-3

ÒÁ 160.25-1

ÒÁ 160.25-2

ÒÁ 160.25-1ó

ÒÁ 160.25-2ó

ÒÁ 160.25-3

ÒÁ 160.25-4

ÒÁ 160.25-5

ÒÁ 200.25-2

ÒÁ 200.25-3

ÒÁÏ 200.25-3

ÒÁÏ 200.25-4

ÒÁÏ 200.25-5

Volume, m³

1,21

1,01

1,86

2,3

2,66

3,9

Weight, t

2,8

2,5

4,7

5,75

6,6

11,2

Thickness of the wall of a pipe, mm

130

110

130

160

150

200

Useful length, mm

2500

2500

2500

2500

2500

2500

Norm of loading in the rail car, items

12

12

4

4

4

4

· Are made of heavy concrete of a class Ñ25/30 (Â30).

· Mark of concrete on water resistance is not bellow than W 6, for lower permeability pipes – W6.

· Mark of concrete on frost resistance – F 200.

· Mark of concrete on water absorption – not more than 6 %.

· Depth of plunging (to pipe top) accordingly:

For the 1st group – 2 m, for the 2nd group – 4 m, for the 3rd group – 6 m, for the 4th group – 8 m, for the 5th group – 10 m.

Sealing elements from rubber are used for weatherproofing of butt connection of pipes.

[1] ó – thicker wall